Sign In | Join Free | My infospaceinc.com
China Wuhan GDZX Power Equipment Co., Ltd logo
Wuhan GDZX Power Equipment Co., Ltd
Verified Supplier

8 Years

Home > Transformer Testing Equipment >

ZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power Transformer

Wuhan GDZX Power Equipment Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

ZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power Transformer

Brand Name : GDZX

Model Number : ZX-BRY02

Certification : ISO9001

Place of Origin : China

MOQ : 1Set

Payment Terms : L/C,T/T,Western Union,MoneyGram,

Supply Ability : 1200Sets/ year

Delivery Time : 8-12 work day

Packaging Details : Carton or wooden case

Price : US $9580.0 - 15699.0/Piece

Product name : Transformer Winding Deformation Tester

Test range : -120dB to +20dB

Test accuracy : 0.1dB

Sweep frequency accuracy : 0.01%

Signal input impedance : 1MΩ

Signal output impedance : 50Ω

Signal output range : +/-20V

Same phase test reproductivity : 99.99%

Carrying box dimension : 410*360*350(mm)

Total weight : 13KG

Contact Now

ZX-BRY02 Transformer Winding Deformation Tester


It is a professional instrument suitable for Internal Structure Fault Detection Of 63kv ~ 500kv Power Transformer.



Product introduction


ZX-BRY02 Transformer Winding Deformation Tester is for testing of power transformer (voltage level at or above 6kV) and other transformers with special purpose. The power transformer is inevitably vulnerable to impulse of various fault short-circuit current or physical collision in the process of operation and transportation. The transformer windings may lose stability under the powerful electro-dynamic force exerted by such short-circuit current, which could result in permanent deformations such as local distortion, swell or dislocation and will severely affect safe operation of the transformer. Deformation of transformer windings can be measured with frequency response analysis method according to national standard DL/T911-2004 for electric power industry, i.e. detect amplitude-frequency response characteristics of each transformer winding and make vertical or horizontal comparison of the detection result to judge possible.


Product advantages

● The instrument is highly intelligent and easy to use, with multiple functions such as automatic range adjustment, automatic sampling frequency adjustment and so on.

● The software adopts windows platform and is compatible with WIN98 / 2000 / WinXP / win7 / win8 / win10 system.

● The instrument has the measurement function of multiple frequency linear sweep measurement system.


Features

1.In the test process only need to remove the transformer connection bus.


2.Sweeping frequency up to 10MHz, scanning interval can be 0.25kHz, 0.5kHz, 1kHz for multiple analysis.


3.High intelligent, auto range adjustment, auto sampling frequency adjustment.


4.Windows platform, compatible with Win98 / 2000 / XP / Win7 / Win8 / Win10 system.


5.Historical curve comparison analysis, max 6 curves observation, auto analysis and diagnosis system.


6.Auto save environment parameters and testing results, color printing function.


7.Humanized software design, more convenient to use.


8.Auto complete the test after wiring, during the measurement check the historical curves or stop at any time.


9.Measurement time less than 60 seconds for every phase, 10 minutes for whole transformer windings.

ZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power Transformer


Technical Indicators
Two sweep methods (1)Linear sweep range (10Hz) - (10MHz) 40000 dots; resolution 0.25kHz, 0.5kHz, 1kHz;
(2)Section sweep range (0.5kHz) - (1MHz), 2000 dots;
Test range -120dB to +20dB
Test accuracy 0.1dB
Sweep frequency accuracy 0.01%
Signal input impedance 1MΩ
Signal output impedance 50Ω
Signal output range +/-20V
Same phase test reproductivity 99.99%
Carrying box dimension 410*360*350(mm)
Total weight 13KG



Product pictures



ZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power TransformerZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power TransformerZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power TransformerZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power TransformerZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power TransformerZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power TransformerZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power TransformerZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power TransformerZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power Transformer






Test cases

ZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power TransformerZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power TransformerZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power Transformer


Company introduction
Wuhan GDZX Power Equipment Co.,Ltd.is a manufacturer of power test equipment, integrating design, production and sales, providing complete solutions for high-voltage testing and electrical testing services for various power users.The main products include:AC series resonance test device, high voltage test equipment, transformer test equipment, secondary protection / switch test equipment, cable fault tester, arrester test equipment, power metering equipment, standard source series and so on. There are many kinds of products and complete models.ZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power Transformer
Service and Warranty
Service
* Provide professional consulting service; dedicated salesman and professional technical engineer to answer customer questions.
* Ensure customer get the detailed information about the product in hand.
* Reasonable price, we trust our customers should get the worth what they paid. Quotation stamped and confirmed by Manager.
* Welcome customers visit.
* The contract and the technical agreement to sign by both parties.
* Being trustworthy, follow the requirements and ensure successful implementation of signed contracts and technical agreements.
* Focus on communication, actively communicate with users, take notes of user’s questions and schedule, provide the necessary technical support.
* Move quick and efficient, professional on delivery, installation, debugging, training and others.
Warranty
* We maintains 100% customer satisfaction, please give us feedback if you fell anything wrong with the product, we will make it right for you.
* Our products are guaranteed with one year warranty and life-long tech support.
* Provide solutions within 24 hours when there is problems feedback from customer.ZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power Transformer

PACKING AND SHIPPING
(1)We will ship products within 5-20 working days after the receipt of confirmation of your payment.
(2)All products will be well packed by robust carton or wooden box so as to ensure goods can arrive safely.
(3)Multiple shipping methods including express, sea freight, railway and so on for your choice, competitive shipping method will be advised to you.
(4)If you go with your own forwarder, we will provide all necessary documents for customs clearance.
(5)After shipping, we will remain attentive till goods well received.
If you need detailed specification, please feel free to contact us.ZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power Transformer


FAQ:

1.Q: Are you trading company or manufacturer?
A: We are manufacturer.

We have R&D department, OEM& ODM services available.




2.Q: How long is your delivery time?
A: We usually arrange shipment within 5-7 working days after checking the payment. However, for example, the delivery time of the complete set of test devices will be a little longer, which needs to be checked in real time.



3.Q: Do you provide samples? Is it free or extra?
A: Yes, we could offer the sample, but not for free; you need pay charge and the cost of freight.



4.Q: What is your term of payment?
A: Payment<=10000USD, 100% in advance. Payment>=10000USD, 30% T/T in advance, balance before shipment.



5.Q: What is the payment method?
A: We can accept Bank Transfer, T/T, PayPal, Western Union, Money Gram, Cash etc.



6.Q: Will you provide OEM service?
A: OEM & ODM services available



7.Q: How long is the product warranty?
A: 1 year.


Product Tags:

15A Circuit Breaker Dynamic Characteristics Analyzer

      

6 Channel Dynamic Characteristics Analyzer

      

Circuit Breaker Dynamic Characteristics Tester

      
Quality ZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power Transformer for sale

ZX-BRY02 Transformer Winding Deformation Tester for Internal Structure Fault Detection of Power Transformer Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Wuhan GDZX Power Equipment Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)